Now connect the copper pipes to the corresponding pipe port with the help of flare nuts. Make sure the flare nuts are tightly closed. Now open both the gas valves. For any queries regarding installing a split air conditioner, please comment in the section below.
I found the very 8 easy steps for installing a split AC. This guide is really helpful as well as informative for summer season. Thank you for sharing your article to us. I am sure many people will come to read this in future. Check Edwards vacuum pump. Is there disadvantage if the outdoor blower has been installed higher than the indoor AC? Many thanks. For keeping outdoor unit blower we hv a neibouring house wall with more than a metre distance space. IST ok. Your email address will not be published.
Currently you have JavaScript disabled. In order to post comments, please make sure JavaScript and Cookies are enabled, and reload the page. Click here for instructions on how to enable JavaScript in your browser. Selecting the right installation area Split AC should be installed on a strong wall that could accommodate the indoor and outdoor unit together. Fix the mounting plate and drill outlet hole Now, hold the mounting plate against the wall where you want to mount the indoor unit.
Loading recommendations Share on Facebook Share. Share on Twitter Tweet. Share on Pinterest Share. Share on Digg Share.
Orient Aeroquiet Review: The new standard in electric fans. How to install RO water purifier in just 10 minutes. Most people who read this article also read 7 important guidelines for split AC installation - June 13, 5 Steps for installing a window AC correctly - February 23, How to install a split air conditioner? He has over 10 years of experience working with HVAC systems.
There are 8 references cited in this article, which can be found at the bottom of the page. This article has been viewed 1,, times. A split system air conditioner is a great option for keeping your home cool and comfortable in the summer months. These units are also quieter, easier to install, and more energy efficient than central air conditioning. Each air conditioning unit is unique to its manufacturer, but the general installation process is the same. Tip: Choose a central location for the indoor unit where the cool air can easily flow through your home, such as in the living room.
However, if you decide to do the work yourself, mount the indoor air conditioning unit on an interior wall away from direct heat or light sources. Run the piping and wiring from the indoor unit through a hole in the wall, then attach a PVC drainage pipe to the unit, running down the exterior of the wall where the unit is attached. Next, install the outdoor condenser on a level concrete pad, then connect the electrical wires and the copper pipes.
Keep reading to learn how to bleed the air and humidity from the refrigerant circuit! Did this summary help you? Yes No. Log in Social login does not work in incognito and private browsers. Please log in with your username or email to continue. No account yet? Create an account. Edit this Article. We use cookies to make wikiHow great. By using our site, you agree to our cookie policy.
Cookie Settings. Learn why people trust wikiHow. Download Article Explore this Article parts. Tips and Warnings. Things You'll Need. Related Articles. Article Summary. Part 1. All rights reserved.
This image may not be used by other entities without the express written consent of wikiHow, Inc. Select an unobstructed location on your interior wall to mount the indoor unit. You'll need to cut a hole through the wall to feed the pipes from the indoor unit to the outdoor unit, so make sure the location you choose will allow you to do so.
Choose a spot away from direct sunlight and heat sources for the best results. Mount the unit 7 feet 2. Install the unit at least 3. The electrical noise from these sources could cause operational problems for your air conditioner.
Avoid locations where gas may leak or where oil mist or sulfur exists. Secure the mounting plate to the interior wall. Hold the mounting plate against the wall where you want to install the indoor unit. Use a level to make sure it is both horizontally and vertically level. Use a pencil to mark the locations of the screw holes, remove the plate, then drill a hole into the wall where each screw will go.
Drill a 3 in 7. Make a mark in the center of the hole in the mounting plate. Use a keyhole saw or a drill with a hole-cutting attachment to create a circular 3 in 7. Check the electrical connections on the indoor unit. Make sure the cable wires are connected to the screw terminals and that the wiring matches the diagram that came with the unit.
Run the pipes and cables through the hole in the wall, then connect them to the unit. Secure the included copper pipes, power cable, and drain pipe together with electrical tape. Place the drain pipe on the bottom to ensure a free flow of water. Run the pipes and cable through the hole in the wall, then secure them to the designated spots on the indoor unit as directed by the instruction manual.
Do your best to minimize how much the pipes and cable bend to ensure that the unit performs well. Make sure that the drainage pipe allows water to drain in an appropriate place. See the instruction manual included with your kit for more information. Secure the indoor unit to the mounting plate. To attach the air conditioner to the wall, simply align the female connections on the back of the unit with the male connections on the mounting plate and press firmly to secure the unit in place.
Make sure the unit tilts backward degrees so that water can flow out of the drain pipe. Part 2. Position the outdoor unit away from any heavily trafficked, dusty, or hot areas. Find the hole you drilled through the mounting plate for the interior unit and position the exterior unit within 50 feet 15 m so the piping and cable can easily be attached.
Make sure that no antenna of a radio or television is within 10 feet 3. Lay a concrete pad on the ground. Secure the outdoor unit on top of the concrete pad. Lay a rubber cushion on top of the pad to minimize vibration, then set the outdoor condenser unit on top of the pad.
Secure the unit to the concrete with anchor bolts. Check the electrical wiring in the outdoor unit. Remove the cover on the condenser. Make any adjustments as necessary. Fasten the cables with a cable clamp and replace the cover. Connect the piping and cable to the outdoor unit. Use flare nuts to secure the 2 copper pipes from the indoor unit to the outdoor unit as per the instruction manual.
Connect the power cable that runs from the indoor unit to the outdoor unit as well. Finally, connect the power supply to a designated outlet. If necessary, you can trim the copper pipes to eliminate excess.